Logo
  • Contact us
  • LK Group
  • English
    • English
    • Deutsch
    • Svenska
    • Italiano
    • YouTube
    • LinkedIn
    • Facebook
    • Instagram
  • Products(current)
  • Support
  • News
  • About us
  • Sustainability
  • LK International
  • Products
    • Ball Valves
    • Capillary fittings - Copper
    • Capillary fittings - Red Brass
    • Check Valves
    • Compression fittings and support sleeves
    • Differential Temperature Controllers
    • Expansion Vessels and Safety Groups
    • Filling Valves
    • Flexible hoses
    • Flowswitch
    • Gaskets
    • Hose clamps
    • Loading Units
    • Manometers & Thermometers
    • Mixing Valves
    • Other Products
    • Prefabrication
    • Pressure Reducing Valves
    • Products for Underfloor Heating
    • Pump Groups
    • Pump Valves & Pump Fittings
    • Safety Valves
    • Solar Pump Units
    • Strainers
    • Temperature Controllers
    • Thermic Valves & Check Valves
    • Threaded fittings - Brass
    • Threaded fittings - Red Brass
    • Valve Actuators
    • Valves for Water Heating
    • Zone Valves
  • Support
    • 840/841 2.0
    • FAQ
      • Products
        • Water meter console
        • What is the running time of a SmartComfort
        • Can you use LK's safety valves with steam?
        • Do all LK 810 ThermoMat spare parts fit the entire range?
        • Is it possible to replace a Honeywell mixing valve with an LK 525 MultiZone with actuator?
        • Can I purchase spare parts for an Acaso 3-way valve in cast iron?
        • I have an RP 12-litre expansion vessel with the port on the long side but I can’t find this product on your website.
        • Why can’t I find the right spare part (sensor body) for my loading unit?
        • SmartComfort shunt exercise
        • I have an LK 550 where I replaced the insert. Now I can´t get out enough heat from it, can I do something about it?
        • How do I clean the filter on a LK 520 MultiFill?
        • What should I do if I have misplaced the air vent to my LK 550 AquaMix?
        • The warm water from my tap is not the correct temperature: what should I do?
        • Why is my safety valve leaking?
        • My mixing valve rotates in different directions: is there something wrong?
        • Unfortunately, I threw away the insulation for my LK 521 MultiFill: can I buy this as a spare part?
        • Can I replace my water meter console with a new version without adaption?
        • Which expansion vessel should I buy?
        • My LK SmartComfort says that the outdoor temperature sensor is missing but, as far as I know, my product doesn’t need one?
        • Is the LK SmartComfort compatible with a mixing valve from another manufacturer?
        • I want to replace my 12 litre expansion vessel: which should I choose?
        • Is it possible to upgrade LK110 to LK130 by purchasing and adding the indoor temperature controller? Or would I need to purchase the whole LK130 set?
        • Air-vent for LK 560 AquaKit as a spare part
        • Byta insats till LK 550 AquaMix
      • Customer service
        • How much does this article cost?
        • Do you have this article in stock?
        • What is the difference between sanitary water and heating water?
        • What is the Kvs value?
        • What does HVAC stand for?
        • Where can I find technical documentation for a product?
        • If I misplace my instrument manual, how can I get hold of a new one?
        • How do I contact customer services?
        • Do you sell directly to consumers?
        • Do you sell directly to installers?
        • Do you have an order question
      • Marketing - Press
        • Where can I download your logotype?
        • What should I do when I need a product photo?
    • Campaign site
    • Applications
      • Heat pump
      • Solvärme
      • Water jacketed stove
      • District heating
      • Water heating
      • Bio fuel
  • News
    • Fairs
      • SHK, 6-9 September 2022
      • GET Nord, 17-19 november 2022
      • ISH, 13-17 March 2023
  • About us
    • Community engagement
    • Opening hours
  • Sustainability
  • LK International
  • Contact us
  • LK Group
  1. Back
  2. Products
  3. Pump Groups
  4. Share
LK HydronicGroup C/C 125 Product image (LKA)
LK HydronicGroup C/C 125 Film (LKA)
LK HydronicGroup C/C 125 Film (LKA)
LK HydronicGroup C/C 125 Film (LKA)
LK HydronicGroup C/C 125 Product image (LKA)
LK HydronicGroup C/C 125 Film (LKA)
LK HydronicGroup C/C 125 Film (LKA)
LK HydronicGroup C/C 125 Film (LKA)
Alla tre på balk _LK HydronicGroup 125.jpg Download image

LK HydronicGroup C/C 125

  • All in one
  • Easy to install
  • Easy to combine with electronic regulation
Technical data
Technical data
  • Voltage: 230 VAC 50/60 Hz
  • Power consumption: 10-75 W, depending on pump speed
  • Working temperature: Min. 5 °C/Max. 95 °C
  • Ambient temperature: Min. 5 °C/Max. 58 °C
  • Max. working pressure: 1.0 MPa (10 bar)
  • Media 1: Water - Glycol mixture max. 50%
  • Thread standard: Rp - female thread, G - male thread
  • Circulating pumps: Wilo PARA 25-180/8-75/SC-12, Wilo Para 25-180/6-43/SC-12, Wilo PARA zKu 8 SC
  • Material, valve body: Brass EN 12165 CW617N
  • Material, insulation: Expanded Polypropylene EPP
LK HydronicGroup is a complete pump group that is suitable for heating where direct supply or mixed supply is desirable. Consists of a highly efficient circulation pump, insulation, wall mounting bracket and two ball valves with thermometer, on the return side there is an integrated check valve.

LK 860 manifold available with or without hydraulic separator for one, two, three optionally four pump groups. Wall mounting bracket are included with the manifold.

LK 861 pump group where direct supply is desired.

LK 862 pump group where mixed supply is desired, a three-way mixing valve is included.

LK 863 pump group where mixed supply is desired, a thermic mixing valve is included. The LK 551 HydroMix has a thermostatic element that regulates the supply and return to achieve the desired supply temperature.

LK 864 pump group with a thermic loading valve LK 823 ThermoVar®. The pump group is intended to ensure both an optimal temperature stratification in the storge tank and high return temperature to the boiler, thus increasing the efficiency of the system.

LK 865 is a complete unit for hot water circulation. Consists of a mixing valve, cross, circulation pump, insulation, connection kit and three check valves. The LK 551 HydroMix mixing valve has a thermostatic element that regulates the supply of both cold and hot water to the desired temperature. The valve has an anti-scald function that closes for incoming hot water if the cold water supply ceases.

LK 866 is a pump group with a four way mixing valve, LK 841 ThermoMix®. The pumpgroup is designed for heating systems where a high return temperature is required to prevent corrosion and thus extend the life length of the heat source.

LK 867 is a pump group with a four way mixing valve, LK 830 ThermoMix® B. The pump group has a 4-way bivalent mixing valve that is designed for heating systems, where energy is taken from two heating units connected in series or parallel or for storage tank systems where energy is extracted from two levels. The pump group should be equipped with an automatic control unit to ensure that the most favourable heat source is prioritised at all times.
Read less
Datasheet Variants
  • Articles
  • Application
  • Accessories & spare parts
  • Downloads

LK 862 - Pump group with mixed supply - Whitout pump

LK 862 - Pump group with mixed supply - Whitout pump Product image (LKA)
LK 862 - Pump group with mixed supply - Whitout pump Measurement drawing (LKA)
LK 862 - Pump group with mixed supply - Whitout pump Product image (LKA)
LK 862 - Pump group with mixed supply - Whitout pump Measurement drawing (LKA)
 
Article no. Dim. Kvs m³/h Weight (kg) Save in my item list
299465 M 1½" / F 1" x M 1½"6.33.1
299466 M 1½" / F 1" x M 1½"10.03.1

LK 860 - Manifold

LK 860 - Manifold Product image (LKA)
LK 860 - Manifold Measurement drawing (LKA)
LK 860 - Manifold Product image (LKA)
LK 860 - Manifold Measurement drawing (LKA)
 
Article no. Type Dim. Note Weight (kg) Save in my item list
182419 Manifold, 1 pc groups with hydraulic separatorM 1½"0.4 MPa (4 bar)5.0
182348 Manifold, 2 pc groups, without hydraulic separatorM 1½"0.4 MPa (4 bar)6.0
182417 Manifold, 4 pc groups, without hydraulic separatorM 1½"0.4 MPa (4 bar)10.0
182350 Manifold, 2 pc groups with hydraulic separatorM 1½"0.4 MPa (4 bar)7.0
182349 Manifold, 3 pc groups, without hydraulic separatorM 1½"0.4 MPa (4 bar)8.0
182351 Manifold, 3 pc groups, with hydraulic separatorM 1½"0.4 MPa (4 bar)9.0

LK 861 - Pump group with direct supply. Whitout pump

LK 861 - Pump group with direct supply. Whitout pump Product image (LKA)
LK 861 - Pump group with direct supply. Whitout pump Measurement drawing (LKA)
LK 861 - Pump group with direct supply. Whitout pump Product image (LKA)
LK 861 - Pump group with direct supply. Whitout pump Measurement drawing (LKA)
 
Article no. Dim. Weight (kg) Save in my item list
299460 M 1½" / F 1" x M 1½"3.1

LK 861 - Pump group with direct supply

LK 861 - Pump group with direct supply Product image (LKA)
LK 861 - Pump group with direct supply Measurement drawing (LKA)
LK 861 - Pump group with direct supply Technical diagram LK 861 - PUMP CHARACTERISTICS LK 861 - PUMP CHARACTERISTICS
LK 861 - Pump group with direct supply Product image (LKA)
LK 861 - Pump group with direct supply Measurement drawing (LKA)
LK 861 - Pump group with direct supply Technical diagram LK 861 - PUMP CHARACTERISTICS
 
Article no. Dim. DN Weight (kg) Save in my item list
299458 M 1½" / F 1" x M 1½"DN 255.0
299459 M 1½" / F 1" x M 1½"DN 325.2

LK 862 R - Pump group with mixed supply - Right version

LK 862 R - Pump group with mixed supply - Right version Product image (LKA)
LK 862 R - Pump group with mixed supply - Right version Measurement drawing (LKA)
LK 862 R - Pump group with mixed supply - Right version Technical diagram LK 862 - Pump Characteristics LK 862 - Pump Characteristics
LK 862 R - Pump group with mixed supply - Right version Product image (LKA)
LK 862 R - Pump group with mixed supply - Right version Measurement drawing (LKA)
LK 862 R - Pump group with mixed supply - Right version Technical diagram LK 862 - Pump Characteristics
 
Article no. Dim. DN Kvs m³/h Weight (kg) Save in my item list
299462 M 1½" / F 1" x M 1½"DN 256.35.3
299464 M 1½" / F 1" x M 1½"DN 3210.05.5

LK 862 L - Pump group with mixed supply - Left version

LK 862 L - Pump group with mixed supply - Left version Product image (LKA)
LK 862 L - Pump group with mixed supply - Left version Measurement drawing (LKA)
LK 862 L - Pump group with mixed supply - Left version Technical diagram LK 862 - Pump Characteristics LK 862 - Pump Characteristics
LK 862 L - Pump group with mixed supply - Left version Product image (LKA)
LK 862 L - Pump group with mixed supply - Left version Measurement drawing (LKA)
LK 862 L - Pump group with mixed supply - Left version Technical diagram LK 862 - Pump Characteristics
 
Article no. Dim. DN Kvs m³/h Weight (kg) Save in my item list
299461 M 1½" / F 1" x M 1½"DN 256.35.3
299463 M 1½" / F 1" x M 1½"DN 3210.05.5

LK 863 - Pump group with thermic mixing valve. Without pump

LK 863  - Pump group with thermic mixing valve. Without pump Product image (LKA)
LK 863  - Pump group with thermic mixing valve. Without pump Measurement drawing (LKA)
LK 863  - Pump group with thermic mixing valve. Without pump Product image (LKA)
LK 863  - Pump group with thermic mixing valve. Without pump Measurement drawing (LKA)
 
Article no. Dim. Note Weight (kg) Save in my item list
299469 M 1½" / F 1" x M 1½"Temperature: 25 - 45 °C4.0

LK 863 - Pump group with thermic mixing valve

LK 863 - Pump group with thermic mixing valve Product image (LKA)
LK 863 - Pump group with thermic mixing valve Measurement drawing (LKA)
LK 863 - Pump group with thermic mixing valve Technical diagram LK 863 - Pump Characteristics LK 863 - Pump Characteristics
LK 863 - Pump group with thermic mixing valve Product image (LKA)
LK 863 - Pump group with thermic mixing valve Measurement drawing (LKA)
LK 863 - Pump group with thermic mixing valve Technical diagram LK 863 - Pump Characteristics
 
Article no. Dim. DN Note Weight (kg) Save in my item list
299467 M 1½" / F 1" x M 1½"DN 25Temperature: 25 - 45 °C5.8
299468 M 1½" / F 1" x M 1½"DN 32Temperature: 25 - 45 °C6.0

LK 864 - Pump group with thermic loading valve

LK 864 - Pump group with thermic loading valve Product image (LKA)
LK 864 - Pump group with thermic loading valve Measurement drawing (LKA)
LK 864 - Pump group with thermic loading valve Technical diagram LK 864 - Pump Characteristics LK 864 - Pump Characteristics
LK 864 - Pump group with thermic loading valve Product image (LKA)
LK 864 - Pump group with thermic loading valve Measurement drawing (LKA)
LK 864 - Pump group with thermic loading valve Technical diagram LK 864 - Pump Characteristics
 
Article no. Dim. DN Kvs m³/h Note Weight (kg) Save in my item list
299470 M 1½" / F 1" x M 1½"DN 259.0Opening temperature: 55 - 70 °C5.7
299471 M 1½" / F 1" x M 1½"DN 329.0Opening temperature: 55 - 70 °C5.9

LK 865 - Complete unit for hot water circulation

LK 865 - Complete unit for hot water circulation Product image (LKA)
LK 865 - Complete unit for hot water circulation Measurement drawing (LKA)
LK 865 - Complete unit for hot water circulation Technical diagram LK 864 - Pump characteristics LK 864 - Pump characteristics
LK 865 - Complete unit for hot water circulation Product image (LKA)
LK 865 - Complete unit for hot water circulation Measurement drawing (LKA)
LK 865 - Complete unit for hot water circulation Technical diagram LK 864 - Pump characteristics
 
Article no. Dim. Note Weight (kg) Save in my item list
299472 F 1" x M 1"Opening temperature: 35 - 65 °C4.9

LK 866 - Pump group with a four way mixing valve, LK 841 ThermoMix®

LK 866 -  Pump group with a four way mixing valve, LK 841 ThermoMix® Product image (LKA)
LK 866 -  Pump group with a four way mixing valve, LK 841 ThermoMix® Product image (LKA)
 
Article no. Dim. DN Kvs m³/h Weight (kg) Save in my item list
299747 M 1½" / F 1" x M 1"DN 256.35.3

LK 867 - Pump group with a four way mixing valve, LK 830 ThermoMix® B

LK 867 -  Pump group with a four way mixing valve, LK 830 ThermoMix® B Product image (LKA)
LK 867 -  Pump group with a four way mixing valve, LK 830 ThermoMix® B Measurement drawing (LKA)
LK 867 -  Pump group with a four way mixing valve, LK 830 ThermoMix® B Product image (LKA)
LK 867 -  Pump group with a four way mixing valve, LK 830 ThermoMix® B Measurement drawing (LKA)
 
Article no. Dim. DN Kvs m³/h Weight (kg) Save in my item list
299765 M 1½" / F 1" x M 1"DN 256.35.3
  • LK HydronicGroup C/C 125 Application image LK 861 - Pump group with direct supply Download image
    LK HydronicGroup C/C 125 Application image LK 861 - Pump group with direct supply
    LK 861 - Pump group with direct supply
  • LK HydronicGroup C/C 125 Application image LK 862 - Pump group with mixing valve Download image
    LK HydronicGroup C/C 125 Application image LK 862 - Pump group with mixing valve
    LK 862 - Pump group with mixing valve
  • LK HydronicGroup C/C 125 Application image LK 863 - Pump group with mixing valve LK 551 HydroMix Download image
    LK HydronicGroup C/C 125 Application image LK 863 - Pump group with mixing valve LK 551 HydroMix
    LK 863 - Pump group with mixing valve LK 551 HydroMix
  • LK HydronicGroup C/C 125 Application image LK 864 - Pump group with thermic loading valve 
LK 823 ThermoVar® Download image
    LK HydronicGroup C/C 125 Application image LK 864 - Pump group with thermic loading valve 
LK 823 ThermoVar®
    LK 864 - Pump group with thermic loading valve
    LK 823 ThermoVar®
  • LK HydronicGroup C/C 125 Application image LK 865 - Complete unit for hot water circulation Download image
    LK HydronicGroup C/C 125 Application image LK 865 - Complete unit for hot water circulation
    LK 865 - Complete unit for hot water circulation
  • LK HydronicGroup C/C 125 Application image LK 861 Right - LK 861 Left Download image
    LK HydronicGroup C/C 125 Application image LK 861 Right - LK 861 Left
    LK 861 Right - LK 861 Left
  • LK HydronicGroup C/C 125 Application image LK 866 -  Pump group with a four way mixing valve, LK 841 ThermoMix® Download image
    LK HydronicGroup C/C 125 Application image LK 866 -  Pump group with a four way mixing valve, LK 841 ThermoMix®
    LK 866 - Pump group with a four way mixing valve, LK 841 ThermoMix®
  • LK HydronicGroup C/C 125 Application image LK 867 - Pump group with a four way mixing valve, LK 830 ThermoMix® B Download image
    LK HydronicGroup C/C 125 Application image LK 867 - Pump group with a four way mixing valve, LK 830 ThermoMix® B
    LK 867 - Pump group with a four way mixing valve, LK 830 ThermoMix® B
LK HydronicGroup C/C 125 Dissection image Spare parts and Accessories Download image
LK HydronicGroup C/C 125 Dissection image Spare parts and Accessories
LK HydronicGroup C/C 125 Dissection image Spare parts and Accessories Download image
LK HydronicGroup C/C 125 Dissection image Spare parts and Accessories
 
Article no. Article Position
187203Wilo PARA 25-180/8-75/SC-121
187322Wilo PARA 25-180/6-43/SC-121
187323Ballvalve, blue2
187324Ballvalve, red2
187325Bracket 3
187326EPP Insulation4
187327Mixing Valve, Kvs 6.35
1873285
187188Sealing kit LK 840/841 DN 25 6
187191Repair kit LK 840 DN 25 7
095349Repair kit 551, 25 - 45 °C (Kvs 3.2-4.2)8
095350Repair kit 551, 35 - 65 °C (Kvs 3.2-4.2)8
187330Repair Kit 823R9
InstructionManual
  • 248184 LK 861-863 HydronicGroup cc125 - Instruction
  • 248186 LK 865 HydronicGroup cc125 - Instruction
  • 248185 LK 864 HydronicGroup 125_864 - Instruction
  • 299747 LK 866 HydronicGroup cc125 - Instruction
  • 299765 LK 867 HydronicGroup cc125 - Instruction
Brochure
  • 248090 LK HydronicGroup - Brochure - ENG

Variants

LK 862 - Pump group with mixed supply - Whitout pump Product image (LKA)

LK 862 - Pump group with mixed supply - Whitout pump

LK 860 - Manifold Product image (LKA)

LK 860 - Manifold

LK 861 - Pump group with direct supply. Whitout pump Product image (LKA)

LK 861 - Pump group with direct supply. Whitout pump

LK 861 - Pump group with direct supply Product image (LKA)

LK 861 - Pump group with direct supply

LK 862 R - Pump group with mixed supply - Right version Product image (LKA)

LK 862 R - Pump group with mixed supply - Right version

LK 862 L - Pump group with mixed supply - Left version Product image (LKA)

LK 862 L - Pump group with mixed supply - Left version

LK 863  - Pump group with thermic mixing valve. Without pump Product image (LKA)

LK 863 - Pump group with thermic mixing valve. Without pump

LK 863 - Pump group with thermic mixing valve Product image (LKA)

LK 863 - Pump group with thermic mixing valve

LK 864 - Pump group with thermic loading valve Product image (LKA)

LK 864 - Pump group with thermic loading valve

LK 865 - Complete unit for hot water circulation Product image (LKA)

LK 865 - Complete unit for hot water circulation

LK 866 -  Pump group with a four way mixing valve, LK 841 ThermoMix® Product image (LKA)

LK 866 - Pump group with a four way mixing valve, LK 841 ThermoMix®

LK 867 -  Pump group with a four way mixing valve, LK 830 ThermoMix® B Product image (LKA)

LK 867 - Pump group with a four way mixing valve, LK 830 ThermoMix® B

Navigation
  • Products
  • Support
  • News
  • About us
  • Opening hours
Support
  • Contact us
  • Movies
  • Catalogues & Brochures
  • Tools
  • Career
  • FAQ
  • Applications
Follow us
  • Newsletter
  • Media center
  • LinkedIn
  • YouTube
  • Facebook
  • Instagram
LK Armatur AB

Garnisonsgatan 49
254 66 Helsingborg 
Sweden

Phone. +46 42-16 92 00

info@lkarmatur.se
order@lkarmatur.se

VAT no: 556249-9508

Cookies

©Lagerstedt & Krantz AB

Our website uses cookies

We use cookies to ensure that we give you the best user experience on our website. By using our website you accept our use of cookies.

Find out more about cookies