Logo
  • Contact us
  • LK Group
  • English
    • English
    • Deutsch
    • Svenska
    • YouTube
    • LinkedIn
    • Facebook
    • Instagram
  • Products(current)
  • Support
  • News
  • About us
  • Sustainability
  • Products
    • Ball Valves
    • Capillary fittings - Copper
    • Capillary fittings - Red Brass
    • Check Valves
    • Compression fittings and support sleeves
    • Differential Temperature Controllers
    • Expansion Vessels and Safety Groups
    • Filling Valves
    • Flexible hoses
    • Flowswitch
    • Gaskets
    • Hose clamps
    • Loading Units
    • Manometers & Thermometers
    • Mixing Valves
    • Other Products
    • Prefabrication
    • Pressure Reducing Valves
    • Products for Underfloor Heating
    • Pump Groups
    • Pump Valves & Pump Fittings
    • Safety Valves
    • Solar Pump Units
    • Strainers
    • Temperature Controllers
    • Thermic Valves & Check Valves
    • Threaded fittings - Brass
    • Threaded fittings - Red Brass
    • Valve Actuators
    • Valves for Water Heating
    • Zone Valves
  • Support
    • 840/841 2.0
    • FAQ
      • Products
        • Water meter console
        • What is the running time of a SmartComfort
        • Can you use LK's safety valves with steam?
        • Do all LK 810 ThermoMat spare parts fit the entire range?
        • Is it possible to replace a Honeywell mixing valve with an LK 525 MultiZone with actuator?
        • Can I purchase spare parts for an Acaso 3-way valve in cast iron?
        • I have an RP 12-litre expansion vessel with the port on the long side but I can’t find this product on your website.
        • Why can’t I find the right spare part (sensor body) for my loading unit?
        • SmartComfort shunt exercise
        • I have an LK 550 where I replaced the insert. Now I can´t get out enough heat from it, can I do something about it?
        • How do I clean the filter on a LK 520 MultiFill?
        • What should I do if I have misplaced the air vent to my LK 550 AquaMix?
        • The warm water from my tap is not the correct temperature: what should I do?
        • Why is my safety valve leaking?
        • My mixing valve rotates in different directions: is there something wrong?
        • Unfortunately, I threw away the insulation for my LK 521 MultiFill: can I buy this as a spare part?
        • Can I replace my water meter console with a new version without adaption?
        • Which expansion vessel should I buy?
        • My LK SmartComfort says that the outdoor temperature sensor is missing but, as far as I know, my product doesn’t need one?
        • Is the LK SmartComfort compatible with a mixing valve from another manufacturer?
        • I want to replace my 12 litre expansion vessel: which should I choose?
        • Is it possible to upgrade LK110 to LK130 by purchasing and adding the indoor temperature controller? Or would I need to purchase the whole LK130 set?
        • Air-vent for LK 560 AquaKit as a spare part
        • Byta insats till LK 550 AquaMix
      • Customer service
        • How much does this article cost?
        • Do you have this article in stock?
        • What is the difference between sanitary water and heating water?
        • What is the Kvs value?
        • What does HVAC stand for?
        • Where can I find technical documentation for a product?
        • If I misplace my instrument manual, how can I get hold of a new one?
        • How do I contact customer services?
        • Do you sell directly to consumers?
        • Do you sell directly to installers?
        • Do you have an order question
      • Marketing - Press
        • Where can I download your logotype?
        • What should I do when I need a product photo?
    • Campaign site
    • Applications
      • Heat pump
      • Solvärme
      • Water jacketed stove
      • District heating
      • Water heating
      • Bio fuel
  • News
    • Fairs
      • MCE, 28 June-1 July 2022
      • SHK, 6-9 September 2022
      • GET Nord, 17-19 november 2022
      • ISH, 13-17 March 2023
  • About us
    • Community engagement
    • Opening hours
  • Sustainability
  • Contact us
  • LK Group
  1. Back
  2. Products
  3. Capillary fittings - Red Brass
  4. Share
Elbow 4090G  Product image (LKA)
4090G Download image

Elbow 4090G

Technical data
Technical data
  • Max. working pressure: See table below
  • Thread standard: R - female thread
  • Other data: Red Brass, according to DIN 1705, ISO 1338
Angle 90°, for heating and cooling systems, domestic water, steam, condensate, air, oil and gas.
Read less
Datasheet Variants
  • Articles
  • Application

4090G - Female /Female Thread

Thread standard according DIN 2999, ISO 7. Manufacturing and quality control in accordance with DIN 2856 chapters 10 and 11.
The dimensions used in the sketch are for illustration only and not part of the specification.

4090G - Female /Female Thread Product image (LKA)
4090G - Female /Female Thread Measurement drawing (LKA)
4090G - Female /Female Thread Product image (LKA)
4090G - Female /Female Thread Measurement drawing (LKA)
 
Article no. Dim. A mm B mm Weight (kg) Save in my item list
2001915 10 x ¼"16150.03
2001923 10 x ⅜"18160.03
2001931 10 x ½"20180.03
2001949 12 x ⅜"19170.04
2001956 12 x ½"20200.05
2001972 15 x ⅜"21190.04
2001980 15 x ½"23220.06
2001998 15 x ¾"26230.05
2002046 18 x ½"25230.05
2002087 22 x ½"28240.07
2002095 22 x ¾"31250.1
2002103 22 x 1"34280.1
2002137 28 x 1"38320.2
2002152 35 x 1"41370.3
2002210 42 x 1½"54450.5
2002236 54 x 2"6452
  • Elbow 4090G  Application image Download image
    Elbow 4090G  Application image

Variants

4090G - Female /Female Thread Product image (LKA)

4090G - Female /Female Thread

Navigation
  • Products
  • Support
  • News
  • About us
  • Opening hours
Support
  • Contact us
  • Movies
  • Catalogues & Brochures
  • Tools
  • Career
  • FAQ
  • Applications
Follow us
  • Newsletter
  • Media center
  • LinkedIn
  • YouTube
  • Facebook
  • Instagram
LK Armatur AB

Garnisonsgatan 49
254 66 Helsingborg 
Sweden

Phone. +46 42-16 92 00

info@lkarmatur.se
order@lkarmatur.se

VAT no: 556249-9508

Cookies

©Lagerstedt & Krantz AB

Our website uses cookies

We use cookies to ensure that we give you the best user experience on our website. By using our website you accept our use of cookies.

Find out more about cookies